Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Comparison of two pressure-sensitive periodontal probes and a manual periodontal probe in shallow and deep pockets
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 13 , Issue 6
November/December 1993

Pages 521-530


Comparison of two pressure-sensitive periodontal probes and a manual periodontal probe in shallow and deep pockets

Rams/Slots


PMID: 8181912
DOI: 10.11607/prd.00.0072

Three periodontal probes--a manual probe and two computerized, pressure-sensitive probes--were studied to determine their relative recording accuracy. In the first part of the study, replicate probing measurements were taken with the three probes at shallow (less than 5 mm) and deeper (greater than or equal to 5 mm) periodontal sites. In the second part of the study, probing depths were determined on all teeth except third molars by the three probing techniques at a single appointment. Mean values between replicate probings for each instrument did not differ statistically, except for duplicate measurements with one of the electronic probes in pockets with depths greater than 5 mm. All three probes demonstrated higher standard deviations with increasing depth, which indicates decreased reproducibility of probing depth measurements. Results of this study suggest that an electronic, pressure-sensitive probe yields more reproducible probing depth measurements than a conventional manual periodontal probe.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help